Pelatihan Keamanan Operasi dan Perawatan Switchgear
Pelatihan Keamanan Operasi dan Perawatan Switchgear – Switchgear (and circuit breakers) are obviously critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. The workshop will discuss application, installation, maintenance and testing issues relating to medium and high voltage switchgear and circuit breakers. There will also be a coverage of low voltage switchgear.
You will receive a thorough grounding in switchgear theory and standards. You will gain a solid understanding of the issues associated with the proper application, installation and maintenance of these critical items of equipment with an overriding emphasis on safety.
This comprehensive and practical workshop emphasises medium voltage switchgear which represents most of the switchgear installed on electrical distribution systems. The focus here is on air blast, oil, SF6 and vacuum circuit breakers. Case studies covering the main manufacturer’s equipment will illustrate the important practical principles. Other power system protection components will be discussed as well to ensure that switchgear is understood in the correct context.
TUJUAN
- • Selection of appropriate type and rating of circuit breakers and switchgear
- • Fundamentals of operation of switchgear
- • Switchgear components (CTs, VTs, relays, cable terminations)
- • Safe operational policies including safety rules and safety documents
- • Diagnostic tools and test equipment
- • Safe maintenance policies including safe working in switch rooms, indoor and outdoor substations
Materi
- Single line diagrams
- Active and passive network components
- Circuit breaker utilisation
- Alternative forms of MV switchgear – ring main units, load breaking/fault making switches,
- Fuse switches
- HV fuses in combination with, and as alternative to circuit breakers
- Auto-reclosers and auto-reclose operation
APPLICATION OF SWITCHGEAR
- Principles of current interruption
- Plain break circuit breakers
- Bulk and small oil volume circuit breakers
- Turbulator (explosion pot)
- Operating mechanisms
- Transfer earth circuit breakers
- Air break and air blast switchgear
- SF6 and Vacuum
- Switchgear in association with disconnectors
- Fixed and withdrawable designs
- Switchgear standards
- Factors affecting switchgear selection
SPECIFICATION OF SWITCHGEAR
- Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents
- Simple and complex protection systems
- Switchgear ancillaries, measurement CTs, VTs, relays
- Cable terminations
- Indoor and outdoor operation
- Substation and switch room layouts and design
SHORT CIRCUIT TESTING
- Symmetrical and asymmetrical breaking
- Make and break operations
- Understanding test oscillograms
SAFETY POLICIES
- General safety precautions and the use of personal protective equipment
- Principles of safety rules
- Principles of personnel authorisation
- Operative training for safe operation of switchgear
- Isolation in a circuit breaker context
- Safety documentation
- Operational and safety locking, caution and danger notices
- Safe working in a substation environment
- Safety interlocks
- Substation alarms
- Individual study task and presentation -safety policies in my company and how they might be improved
OPERATION OF MODERN SWITCHGEAR
ASSET MANAGEMENT IN A SWITCHGEAR CONTEXT
- Principles of time and condition based asset management
- Asset registers
- Asset management systems
DIAGNOSTICS, TESTING & MAINTENANCE
- Switchgear inspection methodologies
- Partial discharge measurement and survey
- Timing tests
- Thermovision
- Mechanisms of deterioration
- Principles of circuit breaker maintenance
- Maintaining oil circuit breakers
- Contact maintenance and contact wipe
- Oil testing
- Maintaining vacuum circuit breakers
- Maintaining SF6 circuit breakers
- SOPs and DINs
- Switchgear defects and defect control systems
Participant
This course is designed for personnel responsible for maintenance, testing and troubleshooting low voltage power circuit breakers, protective relays, breaker trip devices and switchgear panels. The lab provides students with the opportunity to work on a variety of low voltage circuit breakers.
Metode Pelatihan Jadwal/Agenda Pelatihan
- Presentasi
- Diskusi
- Case Study
- Simulation
- Evaluation (Pre and Post Test)
- Kunjungan/Praktek (Menyesuaikan/tentative)- 22-24 Januari 2024
- 12-14 Februari 2024
- 13-15 Maret 2024
- 29-30 April 2024
- 21-23 Mei 2024
- 11-13 Juni 2024
- 16-18 Juli 2024
- 13-15 Agustus 2024
- 17-19 September 2024
- 15-17 Oktober 2024
- 7-9 November 2024
- 26-28 November 2024
- 3-6 Desember 2024
- 17-19 Desember 2024
Lokasi Fasilitas
- Yogyakarta
- Jakarta
- Bandung
- Bali
- Surabaya
- Malang
- Batam
- Lombok- FREE Airport pickup service (Gratis Antar jemput Hotel/Bandara/Stasiun/Terminal) *
- FREE Transporsi Peserta ke tempat pelatihan .
- Module atau Handout
- FREE Flashdisk
- Sertifikat
- FREE Bag or bagpackers (Tas Training)*
- Training Kit (Dokumentasi photo, Blocknote, ATK, etc)
- 2x Coffe Break & 1 Lunch, Dinner
- FREE Souvenir Exclusive
- Training room full AC and Multimedia
S&K berlaku
Catatan :
Hotel untuk pelatihan ada beberapa pilihan seperti Hotel Ibis, Hotel Aston, Hotel Amaris, Hotel Cavinton, Hotel Hyatt, Hotel Grand Aston, Novotel, Hotel Harris, Hotel 101, Hotel Grand Mercure,Ritz Carlton, Hotel Ibis Style dan masih banyak pilihan menarik lainnya.
Apabila perusahaan membutuhkan paket in house training anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan. Dapatkan harga spesial untuk pengiriman minimal 3 peserta dari perusahaan yang sama.
Informasi lebih lanjut :
Tlp./ WA : 0852-9095-1223 || Email : info@diklat-indonesia.com